B. SNMP MIBs, Traps, and RMON Alarm Defaults

9700-A2-GB20-20

December 2002

B-9

Physical Sublayer

(continued)

Synchronous
Data Port

(Supported by the
media-specific
RS232-like MIB.)

ifIndex (RFC 1573)

ifAdminStatus (RFC 1573)

ifOperStatus (RFC 1573)

devLastTrapString
(devHealthAndStatus.mib)

linkDown – One or more alarm
conditions are active on the
port. Alarm conditions include:

– DTR off.

The DTR alarm

condition will only generate
a linkUp/linkDown trap if the
DTE supports the DTR lead
state.

– RTS off. The RTS alarm

condition will only generate
a linkUp/linkDown trap if the
DTE supports the RTS lead
state.

– Not DTR or RTS, but link is

down.

Strings:
‘$ifString $alarmString down.’
(e.g., `Sync Data Port S01P1
DTR and RTS down.’)

‘$ifString administratively shut
down.’ (Due to an intentional
shutdown.)

linkUp – No alarms on the port.

String:
‘$ifString up.’

Ethernet Port

(Supported by an
entry in the MIB-II
Interfaces Table.)

ifIndex (RFC 1573)

ifAdminStatus (RFC 1573)

ifOperStatus (RFC 1573)

devLastTrapString
(devHealthAndStatus.mib)

linkDown – Communication is
not possible over the Ethernet
port.

– Loss of Signal (LOS)

– Loss of Frame (LOF)

– Loss of Link (LOL)

– Loss of Signal Quality

– LPR Events

Strings:
‘$ifString down.’

‘$ifString administratively shut
down.’ (Due to an intentional
shutdown.)

linkUp – Communication on the
Ethernet port is restored.

String:
‘$ifString up.’

Table B-6.

linkUp and linkDown Variable-Bindings (2 of 3)

Interface

Variable-Bindings

Possible Cause