Trap: warmstart, Trap: authenticationfailure – Paradyne 9788 User Manual

Page 247

Advertising
background image

B. SNMP MIBs, Traps, and RMON Alarm Defaults

9700-A2-GB20-20

December 2002

B-7

Trap: warmStart

This trap indicates that the FrameSaver unit has been reset and has stabilized.

Trap: authenticationFailure

This trap indicates that access to the FrameSaver unit was unsuccessful due to
lack of authentication.

Table B-3.

warmStart Trap

Trap

What It Indicates

Possible Cause

warmStart

FrameSaver unit has just
reinitialized and stabilized
itself.

Reset command sent.

Power disruption.

String:
‘Unit reset.’

Variable-Binding

devLastTrapString
(devHealthAndStatus.mib)

Table B-4.

authenticationFailure Trap

Trap

What It Indicates

Possible Cause

authenticationFailure

Access to the FrameSaver
unit was attempted and failed.

SNMP protocol message not
properly authenticated.

Three unsuccessful attempts
were made via a Telnet session
or locally at the asynchronous
terminal to enter a correct login
user ID/password combination.

IP Address security is enabled
and a message was received
from the SNMP Manager
whose address was not on the
list of approved managers.

String:
‘Unauthorized access attempted.’
(e.g., ‘Unauthorized access
attempted from COM port.’)

Variable-Binding

devLastTrapString
(devHealthAndStatus.mib)

Advertising