Paradyne 9788 User Manual

Page 146

Advertising
background image

7. Operation and Maintenance

7-10

December

2002

9700-A2-GB20-20

Limit of Mgmt PVCs
reached

New was selected from the
PVC Connection Table and
the maximum number of
management PVCs has
already been created.

Do not create the management
PVC.

Delete another management
PVC, and try again.

Limit of PVC
Connections reached

The maximum number of
PVCs has already been
created and New was
selected from the PVC
Connection Table.

Do not create the PVC
connection.

Delete another PVC connection,
and try again.

Name Must be Unique

Name entered for a
management PVC has
been used.

Enter another 4-character name
for the logical/management link.

No Circuits available
for Mgmt PVC

New was selected from the
Management PVCs screen,
but no unconnected frame
relay Link/DLCI/EDLCI or
ATM Link/VPI/VCI has been
defined that can be used in
a management PVC.

Define a new frame relay
Link/DLCI/EDLCI or ATM
Link/VPI/VCI for the management
PVC.

No Destination Link
DLCIs Available

New was selected from the
PVC Connection Table, but
no DLCIs are available on
the network link.

Even though DLCIs are available
to form a connection, configure
additional DLCIs for the network
link and try again.

No DLCIs available for
connection

All configured DLCIs have
been connected but New
was selected from the PVC
Connection Table.

No action needed, or configure
additional DLCIs and try again.

All Link/DLCI pairs have
been connected but New
was selected from the
Management PVCs screen.

Configure additional network
and/or Port-1 Links/DLCIs pairs
and try again.

No DLCIs Available for
Mgmt PVC

All configured DLCIs have
been connected but New
was selected from the
Management PVCs screen.

Configure additional network
and/or Port-1 DLCIs and try again.

No DLCIs Defined

DLCI Records was selected
from an interface’s
Configuration Edit menu,
and no DLCI Records have
been created for this
interface.

Select New and create a DLCI
record.

No more DLCIs
allowed

New or CopyFrom was
selected from an interface’s
DLCI Records screen, and
the maximum number of
DLCI Records had already
been reached.

Delete a DLCI, then create the
new DLCI Record.

Table 7-3.

Device Messages (3 of 5)

Message

What It Indicates

What To Do

Advertising