4. Configuration Options

4-44

December

2002

9700-A2-GB20-20

Primary EDLCI

Possible Settings: 0 – 62
Default Setting: Initially blank

Specifies the EDLCI number used by a management PVC when a multiplexed DLCI is
selected. EDLCIs identify unique individual connections within multiplexed DLCIs.

Use 0 to identify the primary EDLCI. Use 1 – 62 to identify secondary EDLCIs. Use the
primary EDLCI for customer data, which has a higher utilization rate than management
data, with slightly less line overhead.

Display Conditions – This option does not appear if the DLCI field does not reference a
multiplexed DLCI, if Network 1 FRF.8 Encapsulation Mode is set to Translational (see

Table 4-12, Network ATM Options

), or if Payload Managed is enabled.

NOTE: Clearing the DLCI or changing to a standard DLCI suppresses the EDLCI field.

0 – 62 – Specifies the EDLCI number.

Primary VPI,VCI Number

Possible Settings:

– VPI: 0 – 15

– VCI: 32 – 255

Default Setting:

If Payload Managed is disabled: Blank.

If Payload Managed is enabled: Lowest VPI, VCI number of a non-management
circuit found in the network.

This option represents the VPI,VCI of the primary link. If Payload Managed is enabled,
this option specifies the VPI,VCI for the payload managed PVC.

Display Conditions – This option appears for an ATM link.

0 – 15 – Specifies the VPI.

32 – 255 – Specifies the VCI.

Table 4-19. Management PVC Options (3 of 4)