Dialing Plan configuration

Page 183 of 258

Main Office Configuration for Survivable Remote Gateway 50

Configuration Guide

ESN Special Numbers are configured in LD 90. Respond to the
prompts as follows:

• TRAN — Enter the Access Code.

• TYPE — Enter SPN for this configuration, as the ZDP value
configured in step 3 on

page 178

is usually a unique non-dialable

number.

• SPN — Enter the ZDP value plus enough digits to distinguish the
type of number, such as national, international, or local. There must
be enough SPN entries to route all valid dialed numbers (see the
example in this section).

• FLEN — Enter the number of digits that are expected for the call
type.

• RLI — Enter the RLI configured in LD 86 in step b on

page 189

.

The RLI routes the call to the NRS with the correct type of number.

• CLTP — Enter the type of call defined by this Special Number:
local (LOCL), national (NATL), or international (INTL).

For example, assume the following:

• AC1 = 1, ZACB = AC1 AC1, and ZDP = 101

• Customer number = 0

• Long-distance calls start with “1”, have 11 digits, and use
RLI = 10 and DMI = 10.

• Local calls start with “5” or “6”, are seven digits long, and use
RLI = 30 and DMI = 30.

Note: RLI and DMI values do not have to be the same, but for clarity, it
may be useful to set them the same.

>LD

90

REQ

NEW

CUST 0

FEAT NET

TRAN AC1

TYPE SPN

SPN

1011

FLEN 14

11 digits for long-distance + 3 digits for ZDP

...

RLI

10