Dialing Plan configuration

Page 215 of 258

Main Office Configuration for Survivable Remote Gateway 50

Configuration Guide

Configuration

To configure the main office:

Configure the ESN Control Block for CDP in LD 86.

> LD 86

REQ NEW

CUST 0

FEAT ESN

CDP YES

MXSC 50

NCDP 4

DLTN YES

Configure the CDP Distant Steering Code (DSC) in LD 87.

> LD 87

REQ NEW

CUST 0

FEAT CDP

TYPE DSC

DSC 4

FLEN 4

RLI 12

To configure the NRS (H.323 Gatekeeper):

Create CDP Domain: “MO_BO_CDP”.

Create H.323 endpoints: “MO”, “BO”.

Create Numbering Plan entries in CDP Domain:

— Add “4” for endpoint “BO”.

— Add “30” for endpoint “MO”.

To configure the SRG:

Set the BUID to the same number that was assigned for the TN by the
main office.

Set the main office VoIP Trunk Access code to 0.

Do not assign a value to the main office trunk access code field.