Nortel Networks Remote Gateway 50 User Manual
Page 210

Page 210 of 258
Dialing Plan configuration
553-3001-207 Standard 2.00 January 2006
Configuration
To configure the main office:
•
Configure the ESN Control Block for CDP in LD 86.
> LD 86
REQ NEW
CUST 0
FEAT ESN
CDP YES
MXSC 50
NCDP 4
DLTN YES
•
Configure the CDP Distant Steering Code (DSC) in LD 87.
> LD 87
REQ NEW
CUST 0
FEAT CDP
TYPE DSC
DSC 50
FLEN 4
RLI 12
To configure the NRS (H.323 Gatekeeper):
•
Create CDP Domain: “MO_BO_CDP”.
•
Create H.323 endpoints: “MO”, “BO”.
•
Create Numbering Plan entries in CDP Domain:
— Add “30” for endpoint “BO”.
— Add “32” for endpoint “MO”.
To configure the SRG:
•
Configure DN and BUID as the same number on each of the redirected
IP Phones. For example, DN/BUID = 32XX.
•
Set the main office VoIP Trunk Access code to 6. For example, main
office VoIP trunk access code = 6.