Dialing Plan configuration

553-3001-207 Standard 2.00 January 2006

Configuration

To configure the main office:

Configure the ESN Control Block for CDP in LD 86.

> LD 86

REQ NEW

CUST 0

FEAT ESN

CDP YES

MXSC 50

NCDP 4

DLTN YES

Configure the CDP Distant Steering Code (DSC) in LD 87.

> LD 87

REQ NEW

CUST 0

FEAT CDP

TYPE DSC

DSC 50

FLEN 4

RLI 12

To configure the NRS (H.323 Gatekeeper):

Create CDP Domain: “MO_BO_CDP”.

Create H.323 endpoints: “MO”, “BO”.

Create Numbering Plan entries in CDP Domain:

— Add “30” for endpoint “BO”.

— Add “32” for endpoint “MO”.

To configure the SRG:

Configure DN and BUID as the same number on each of the redirected
IP Phones. For example, DN/BUID = 32XX.

Set the main office VoIP Trunk Access code to 6. For example, main
office VoIP trunk access code = 6.