Operation, administration, and maintenance (OAM) features 2-77

Planning and Ordering Guide—Part 1 of 2 NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004

Small Form Factor Pluggables (SFP) alarms

Table 2-10 on page 2-77

, lists equipment alarms associated to the small form

factor pluggables (SFP) modules.

Ingress LAN port alarms

Table 2-11 on page 2-78

, lists the ingress LAN port alarms which apply to both

the Ethernet and Fibre Channel.

Figure 2-36 on page 2-80

, provides a graphical representation of the ingress

LAN port alarms.

Table 2-10
Small Form Factor Pluggable (SFP) alarms

Alarm

Description

Severity

Circuit Pack Missing -
Pluggable

This alarm is raised when a provisioned
Small Form Factor Pluggable (SFP)
optical transceiver module is not
physically installed in the
2xGigE/FC-P2P circuit pack.

Critical, service affecting (C,SA)
Minor, non service affecting, (mn,nsa)
See

Note

Circuit Pack Mismatch -
Pluggable

This alarm is raised when an
unsupported Small Form Factor
Pluggable (SFP) optical transceiver
module is installed in a provisioned
subslot on a 2xGigE/FC-P2P circuit
pack.

Critical, service affecting (C,SA)
Minor, non service affecting, (mn,nsa)
See

Note

Circuit Pack Unknown -
Pluggable

This alarm is raised when an
unsupported Small Form Factor
Pluggable (SFP) optical transceiver
module is installed in a unprovisioned
subslot of a 2xGigE/FC-P2P circuit pack.

Critical, service affecting (C,SA)
Minor, non service affecting, (mn,nsa)
See

Note

Circuit Pack Fail - Pluggable

This alarm is raised when a Small Form
Factor Pluggable (SFP) optical
transceiver module provisioned on a
2xGigE/FC-P2P circuit pack fails.

Critical, service affecting (C,SA)
Minor, non service affecting, (mn,nsa)
See

Note

Note: The severity of the alarm becomes a minor, non-service affecting (mn, nsa) if there are no