Nortel Networks OPTera Metro 3500 User Manual

Page 127

Advertising
background image

Operation, administration, and maintenance (OAM) features 2-89

Planning and Ordering Guide—Part 1 of 2 NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004

WAN facility

Table 2-15 on page 2-89

, lists facility parameters supported by the

2xGigE/FC-P2P WAN interface.

Table 2-15
2xGigE/FC-P2P WAN port signal attributes

Signal Attribute

Definition

Values
(See Note

1

)

Access
(see Note

2

)

RATE
(Basic rate)

Is used to indicate the basic rate assigned
to that facility.

None,STS1, STS3C,
STS12C, STS24C

R/O

PROVUNITS
(Bandwidth units)

Is used to indicate the number of
provisioned bandwidth units in the
SONET/SDH transmit direction. The unit
is specified by the RATE attribute.
Possible values when VCAT=ENABLE
are 0..7 (when RATE is STS3c) or 0..21
(when RATE is STS1).

Possible values when
VCAT=DISABLE are 0 or 1.
Possible values when
VCAT=ENABLE are 0..7
(when RATE is STS3c) or
0..21 (when RATE is STS1).

R/O

ACTUALUNITS
(Units carrying traffic)

Is used to indicate the number bandwidth
unit actually carrying traffic in the
SONET/SDH transmit direction.

Possible values when
VCAT=DISABLE, or
VCAT=ENABLE and
LCAS=DISABLE are either 0
or PROVTXUNITS. It will
return UNKNOWN is the card
is not present in the shelf

R/O

MAGICNUM
(Magic number)
(See Note

6

)

Enables or disables the use of a magic
number to distinguish between two peers
and detect error conditions. Can be used
to determine whether trying to establish a
link with one self.

Disable
(See Note

3

)

R/O

FCS
(Frame checksum
size)
(See Note

6

)

Size of the FCS to be used to transmit
packets.

0, 32
(See Note

4

)

R/W

LCM
(Link connectivity
monitor)
(See Note

6

)

Is used to control the Link Connectivity
Monitor functionality.

Disable
(See Note

3

)

R/O

MAPPING
(Mapping protocol)
(See Note

6

)

Client signal to SONET mapping protocol GFP-F (default when LAN

facility is Ethernet),
GFP-T (default and only
option when LAN facility is
Fibre Channel)

R/W

MODE
(Mode)

Identifies if the port operates in SONET or
SDH mode.

Sonet, SDH

R/O

VCAT
(Virtual
Concatenation)

Indicates if Virtual Concatenation is
enabled or not on this port. Can only be
edited if there are no cross-connections.

Enable, Disable
(See Note

5

)

R/W

Advertising
This manual is related to the following products: