Operation, administration, and maintenance (OAM) features 2-163

Planning and Ordering Guide—Part 1 of 2 NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004

Figure 2-53
Test access-monitor state

EX1397t

The monitoring configurations supported include:

Single Facility Access Digroup, Monitor Equipment side (Single FAD,
MONE) see

Figure 2-54

Single Facility Access Digroup, Monitor Facility side (Single FAD,
MONF) see

Figure 2-55

Dual Facility Access Digroup, Monitor Equipment and Facility sides
(Dual FAD, MONEF) see

Figure 2-56

Note: In

Figure 2-54

to

Figure 2-57

“equipment side” and “facility side”

shows the direction(s) of the connection under test.

Single FAD, MONE and Single FAD MONF

In a single FAD environment, only one direction of the signal can be monitored
at a time.

In the case of Single FAD, MONE, the monitored connection is from the
equipment side input to the facility side output, see A transmission path as
shown in

Figure 2-54

.

In the case of Single FAD, MONF, the monitored connection is from the
facility side input to the equipment side output, see B transmission path as
shown in

Figure 2-55

.

Input

Output

Test

Unit

TAP Out