Nortel Networks OPTera Metro 3500 User Manual

Page 158

Advertising
background image

2-120 Operation, administration, and maintenance (OAM) features

OPTera Metro 3500 Multiservice Platform NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004

Protection performance monitoring parameters for optical facilities

The OPTera Metro 3500 network elements support the following protection
performance monitoring (PM) parameters for OC-3, OC-12, OC-48 and
OC-192 facilities:

protection switch count-working (PSC-W)

protection switch count-protection (PSC-P)

protection switch duration (PSD)

The protection PM parameters are available for OC-3, OC-12, OC-48 and
OC-192 facilities (see

Note

). When the facilities are not protected, the

protection PM parameters are fixed at 0.

Note: Protection PM parameters are not available for the OC-3 optical
interface, EC-1x3, and EC-1x12 circuit packs. For these circuit packs, the
protection PM parameters are fixed at 0.

OC-3, OC-3x4, OC-12, OC-12x4,
OC-48, OC-192 (1+1 unidirectional,
bidirectional line nonrevertive)

• Lockout

• Autonomous (line failures on protection)

• Forced

• Autonomous (line failures on working)

• Manual

• High-speed exerciser

OC-48 (2-Fiber BLSR) (revertive)
OC-192 (2-Fiber BLSR) (revertive)

• Lockout (protection/working)

• Forced Switch of Working - Ring

• Signal Failed on Working - Ring

• Signal Degraded on Protection

• Signal Degraded on Working - Ring

• Manual Switch of Working - Ring

• Wait to Restore

• Exerciser - Ring

• Reversed Request - Ring

Note: DS1 user protection switch requests (including manual, forced and lockouts)
are automatically cleared after a network element power failure/recovery.

Table 2-27 (continued)
Services protection priority

Circuit pack

Protection priority

Advertising
This manual is related to the following products: