2-54 Operation, administration, and maintenance (OAM) features

OPTera Metro 3500 Multiservice Platform NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004

Facility attributes

Visible and provisionable facility attributes include the following:

Signal degrade threshold (SDTH)

Auto in service (AINS)

Section trace

Path trace

Equalization (DS1)

Frame Format (DS1)

Line build out (DS3, EC-1)

DS1, DS3, and EC-1 loopbacks

All supported facility attributes (except loopbacks) are default provisioned
when equipment is provisioned.

Loopbacks

Terminal loopback

A terminal loopback routes an incoming signal towards the backplane. An
alarm indication signal (AIS) is generated in the outward direction of the
signal.

Facility loopback

During a facility loopback, a signal received on the optical or electrical side of
the facility is looped back towards the associated return transmitter An alarm
indication signal (AIS) is generated in the onward direction of the signal. To
operate a facility loopback, the facility must be manually put out of service
(OOS).

Note: The facility must be out-of-service before a loopback is permitted
and both types of loopback cannot be active for a given facility at the same
time.

Facility loopback implementation complies with the latest issues of:

GR-253-CORE, Synchronous Optical Network (SONET) Transport
Systems: Common Generic Criteria

GR-819-CORE, Network maintenance: Access and Testing - Special
Services (SS) and SS-like networks

Refer to

Figure 2-29

for details on electrical loopback types.