Protection switching, Protection switching 3-88 – Nortel Networks OPTera Metro 3500 User Manual

Page 316

Advertising
background image

3-88 Hardware feature descriptions

OPTera Metro 3500 Multiservice Platform NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004

DS3x3 mappers are installed in pairs and DS3 protection switching is 1+1
non-revertive.

The DS3x3 circuit pack can be installed in slots 3 through 10. DS3x3 circuit
packs are installed in pairs. The first DS3x3 circuit pack of the pair is installed
in an odd slot. The second DS3x3 circuit pack of the pair is installed in the
adjacent even slot. The second DS3x3 circuit pack functions as the protection
DS3x3 circuit pack for the working circuit pack in the odd slot.

The maximum number of working DS3x3 circuit packs that can be inserted in
a shelf is four.

See

Table 3-3 on page 3-6

for operational temperature ranges.

Note 1: If there is a 1-28 DS1 I/O module installed, and if slots 5 and 6 are
not equipped with DS1 mappers, you may not install DS3x3 circuit packs
in slots 5 or 6 (there is not enough room for slot 5 or slot 6’s BNC I/O
modules).

Note 2: If there is a 29-56 DS1 I/O module installed, and if slots 7 and 8
are not equipped with DS1 mappers, you may not install DS3x3 circuit
packs in slots 7 and 8 (there is not enough room for slot 7 or slot 8’s BNC
I/O modules).

Note 3: If there is a 29-84 DS1 I/O module installed, and if slots 7 through
10 are not equipped with DS1 mappers, you may not install DS3x3 circuit
packs in slots 7 through 10 (there is not enough room for slot 7 through slot
10’s BNC I/O modules).

Protection switching

DS3x3 protection switching is 1+1 non-revertive. If a working DS3x3 mapper
becomes defective, the traffic is switched to the protection DS3x3 mapper.
Switching can also take place under user control.

Alarm LED definitions

The following table provides a list of LEDs of the DS3x3 mapper. See

Figure

3-28 on page 3-47

for the DS3x3 mapper faceplate layout showing the location

of the LEDs.

LED

Color

Description

Status (top)

Red

Circuit pack failure

Status (bottom) Green

DS3x3 equipment is active and at least one DS3 line
facility is in service with at least one cross-connect

LOS (1-3)

Yellow

Loss of signal on the port