Ds3x12 / ds3x12e mapper, Equipping rules, Ds3x12 / ds3x12e mapper 3-89 – Nortel Networks OPTera Metro 3500 User Manual

Page 317: Equipping rules 3-89

Advertising
background image

Hardware feature descriptions 3-89

Planning and Ordering Guide—Part 1 of 2 NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004

DS3x12 / DS3x12e mapper
(NTN435AA, AH) / (NTN435BA)

The DS3x12 mapper (NTN435AA, NTN435AH) and DS3x12e (NTN435BA)
mapper have 12 DS3 ports which function independently. Each mapper’s
bandwidth capacity is 12 DS3 signals added/dropped in each slot. Each
OPTera Metro 3500 shelf’s capacity is 48 DS3 add/drop signals, with 1+1
equipment protection for each circuit pack.

Mappers are installed in pairs and DS3 protection switching is 1+1
non-revertive for each mapper.

The DS3x12e mapper (NTN435BA) has the same functionality as the DS3x12
mapper (NTN435AA, NTN435AH), plus additional path PMs and alarms as
follows:

Note: Neither the DS3x12 mapper, the DS3x12e mapper nor DS3 services
are VT managed.

DS3 Path PMs (Near-End) available only on DS3x12e mapper

CV-P (Coding Violation - Path) on DS3 Rx

ES-P (Errored Second - Path) on DS3 Rx

SES-P (Severely Errored Second - Path) on DS3 Rx

UAS-P (Unavailable Second - Path) on DS3 Rx

DS3 alarms available only on DS3x12e mapper

’DS3 Rx Frequency out of Range’ - DS3 is out of frequency in the Rx
direction

’DS3 Rx Parity > 10E-6’ - DS3 parity error rate exceeds 10E-6 in the Rx
direction

’DS3 Tx Frequency out of Range’ - DS3 is out of frequency in the Tx
direction

’STS Path Trace Mismatch’ - Path trace mismatch detected

Equipping rules

Connectivity for the twelve DS3 signals at each slot is through the BNC
12-Port Front I/O module (NTN452JA) on the OPTera Metro 3500 shelf
(NTN476AA, NTN476DA). On the OPTera Metro 3500 Universal Shelf
(NTN476AH) you must use the BNC 12-Port Front Enhanced I/O module
(NTN452JH) or the BNC 12-Port Rear I/O module (NTN452KA).

The DS3x12 / DS3x12e mapper can be installed in slots 3 through 10. Mappers
are installed in pairs. The first mapper of the pair is installed in an odd slot. The
second mapper of the pair is installed in the adjacent even slot. The second
mapper functions as protection for the working mapper in the odd slot.