Nortel Networks OPTera Metro 3500 User Manual

Page 195

Advertising
background image

Operation, administration, and maintenance (OAM) features 2-157

Planning and Ordering Guide—Part 1 of 2 NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004

Synchronization-status messages are carried in bits 5 through 8 of the S1 byte
in the SONET line overhead and in the extended superframe (ESF) datalink of
the external DS1 signal from a BITS or a tributary. As the timing is passed
from one network element to the next, each network element sends SSMs. If
the quality of the timing changes, the SSMs inform the next network element
of the change. See

Table 2-33

.

Table 2-33
Synchronization status messages and quality levels

Description

Quality
level

SONET S1 byte
(bit 5 to bit 8)

Designation

ESF datalink
code byte

Stratum 1—Traceable

1

0001

ST1 (PRS)

000010

Synchronized—
Traceability unknown

2

0000

STU

000100

Stratum 2—Traceable

3

0111

ST2

000110

Stratum 3—Traceable

4

1010

ST3

001000

SONET minimum
clock—Traceable

5

1100

SMC

010001

Stratum 4—Traceable
(see Note 1)

6

n/a

ST4

010100

Do not use for
synchronization

8

1111

DUS

011000

Reserved for network
synchronization use
(holdover)

7

1110

RES

100000

Note 1: The ST4 message is carried in the ESF datalink of an external DS1 timing
signal, not in the SONET overhead.

Note 2: Any unsupported synchronization status message S1 or DS1 ESF datalink
is byte-mapped to a DUS designation.

Advertising