2-166 Operation, administration, and maintenance (OAM) features

OPTera Metro 3500 Multiservice Platform NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004

Figure 2-58
Split test access-Single FAD, SPLTE

Ex1402

In the case of Single FAD, SPLTF, both the A and B paths are interrupted with
the input of B path-facility side going to the TAP input and the output to A
path-facility side as shown in

Figure 2-59

.

Figure 2-59
Split test access-Single FAD, SPLTF

EX1403

In the case of Single FAD, SPLTA, the A path is split and connected on both
the right side (facility side) and left side (equipment side) of the accessed
circuit to the FAD as shown in

Figure 2-60

.

Figure 2-60
Split test access-Single FAD, SPLTA

EX1405

A Path

B Path

TAP

To Aid

AIS

From Aid

Facility
side

Equipment
side

A Path

B Path

TAP

To Aid

AIS

From Aid

Facility
side

Equipment
side

A Path

B Path

TAP

Odd

channel

From Aid

To Aid

Facility
side

Equipment
side