3-98 Hardware feature descriptions

OPTera Metro 3500 Multiservice Platform NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004

Alarm LED definitions

The following table provides a list of the OPTera Packet Edge 2xGigE circuit
pack LEDs. See

Figure 3-28 on page 3-47

for the 2xGigE faceplate layout.

2xGigabit Ethernet/Fibre Channel - Point-to-Point circuit pack
(NTN438DA)

The 2xGigE/FC-P2P circuit pack also provides 2 independent LAN ports
allowing for transport of Gigabit Ethernet or Fibre Channel signals across a
SONET network where the traffic can be groomed, switched and monitored by
the network,

The 2xGigE/FC-P2P circuit pack allows a fiber LAN tributary interface to
connect directly to the circuit pack faceplate. The 2xGigE/FC-P2P circuit pack
supports contiguous and virtual concatenation connections, refer

Bandwidth

management on page 2-84

Equipping rules

The OPTera Metro 3500 shelf supports eight OPTera Packet Edge
2xGigE/FC-P2P circuit packs in slots 3 through 10. 2xGigE/FC-P2P circuit
packs only operate in an unprotected mode.

Users can install only 2x100BT-P2P, 4x100BT, 4x100FX and 2xGigE/FC-P2P
circuit packs in adjacent slots.

LED

Color

Description

Status

Red

When active, indicates that a circuit pack
equipment failure has been detected.

Active

Green

When active, indicates that the circuit pack is
active and either at least one of the LAN ports is
IS (Data) or at least one cross-connect exists
(SONET).

WAN

Yellow

Active when the circuit pack has at least one
cross-connect and is attached to an OPTera
Packet Edge System ring and either the east,
west, or both WAN ports are experiencing an
STS path problem.

Link (1-2)

Yellow

Active when the administrative state of one of
the two LAN ports is up and the operational state
is down.

Advertising