Hardware feature descriptions 3-99

Planning and Ordering Guide—Part 1 of 2 NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004

If a 4x100BT, 4x100FX, 2x100BT-P2P or 2xGigE/FC-P2P circuit pack is
inserted into an odd slot (n

odd

), then you can only insert one of the following

circuit packs into the odd slot (n

odd

+1):

2x100BT-P2P

4x100BT

4x100FX

2xGigE/FC-P2P

If a 4x100BT, 4x100FX, 2x100BT-P2P or 2xGigE/FC-P2P circuit pack is
inserted into an even slot (n

even

), then you can only insert one of the following

circuit packs into the odd slot (n

even

-1):

2x100BT-P2P

4x100BT

4x100FX

2xGigE/FC-P2P

Note: There is no equipment protection for 2xGigE/FC-P2P circuit packs.

The 2xGigE/FC-P2P circuit packs supports two SFP optic modules. Each SFP
module is offered in either short reach (SX, NTTP51AA), long reach (LX,
NTTP51BD) and extended reach (ZX, NTTP51DZ) range. A dust cap
(A0512434) is required for any unequipped port.

Note 1: Support with VTX-series or STX-192 circuit packs in slots 13 and
14.

Note 2: The 2xGigE/FC-P2P circuit pack is shipped with two dust caps
(A0512434).

See

Table 3-3 on page 3-6

for operational temperature ranges and operating

distances.