Hardware feature descriptions 3-61

Planning and Ordering Guide—Part 1 of 2 NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004

Alarm LED definitions

The following table lists the OC-192 interface circuit pack LEDs.

The following table lists the modified alarms associated to the OC-192 interface circuit
pack.

Note: When the OC-192 circuit pack receives an unequipped signal on
concatenated traffic rates (STSnC) connections, the OC-192 circuit pack
will raise an UNEQ alarm: "STS3C Rx Unequipped, STS12C Rx
Unequipped, STS24C Rx Unequipped, or STS48C Rx Unequipped".

LED

Color

Description

Status (top)

Red

Circuit pack failure

Yellow Loss

of

signal

Status (bottom)

Green

In service and carrying traffic

Alarm Text or conditions

Default k-bytes

Invalid K-bytes

Node ID mismatch

Traffic Squelched

Wait to Restore

Wait to Restore - Remote

Lockout of Protection Complete - Remote

Lockout of Protection Complete

Lockout of Working Complete

Manual Switch Complete

Manual Switch Complete - Remote

Force Switch Complete

Force Switch Complete - Remote

Protection switch Fail

Auto Switch Complete

Protection Exerciser Failed

Protection Exerciser Complete