Operation, administration, and maintenance (OAM) features 2-107

Planning and Ordering Guide—Part 1 of 2 NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004

SES-PFE

Severely errored
seconds, path, far-end

• SONET: Count of one second intervals with

FEBE-P >=2400 or RDI-P >=1

• DS1-ESF: Count of one second PRM intervals

with (G6=1 or SE=1) in the PRM or RAI signal,
receive and transmit

SEFS-PFE

Severely errored
frame, path, far-end

• SONET: Count of one second intervals with

FEBE-P >=2400 or RDI-P >=1

• DS1-ESF: Count of one second PRM intervals

with (G6=1 or SE-1) in the PRM or RAI signal

SAS-P

Severely errored frame
/ alarm indication
signal (AIS) seconds,
path

• DS3: Count of one second intervals with any

SEF >=1 or AIS >=1, receive and transmit

• DS1: Count of one second intervals with SEF

>=1 or AIS >=1, receive and transmit

SEFS-P

Severely errored
frame, path

• DS1-ESF: Count of one second PRM intervals

with SE bit=1 in the PRM, receive and transmit

ALS-P

AIS / LOP seconds,
path

• SONET: Count of one second intervals with

AIS-P >=1 or LOP-P >=1

ALS-PFE

AIS / LOP seconds,
path, far-end

• SONET: Count of one second intervals with

RDI-P >=1

UAS-P

Unavailable seconds,
path

• SONET: Count of the seconds during which the

STS Path was considered unavailable

• DS3x3 / DS3x12e: Count of the seconds during

which the STS Path was considered
unavailable, receive and transmit

• DS3x12: Count of the seconds during which the

STS Path was considered unavailable, transmit
only

• DS1: Count of the seconds during which the

STS Path was considered unavailable, receive
and transmit

UAS-PFE

Unavailable seconds,
path, far-end

• SONET, DS1-ESF: Count of the seconds during

which the STS Path was considered
unavailable, receive and transmit