Connecting AI Signals on the USB-6210/6211 Devices

NI USB-621x User Manual

5-6

ni.com

Figure 5-2. Differential Connections for Floating Signal Sources with Single Bias

Resistor

You can fully balance the signal path by connecting another resistor of the
same value between the positive input and AI GND on the USB-621x
device, as shown in Figure 5-3. This fully balanced configuration offers
slightly better noise rejection, but has the disadvantage of loading the
source down with the series combination (sum) of the two resistors. If, for
example, the source impedance is 2 k

Ω and each of the two resistors is

100 k

Ω, the resistors load down the source with 200 kΩ and produce a –1%

gain error.

+