Chapter 6

Connecting AI Signals on the USB-6215/6218 Devices

© National Instruments Corporation

6-3

NI USB-621x User Manual

The differential connection configuration allows the common-mode noise
voltage, V

cm

, to be rejected during the measurement of V

1

.

You must connect the negative lead of your sensors and AI GND to a local
ground signal on your system.

Referenced Single-Ended (RSE) Measurements

Using the RSE measurement configuration allows the USB-6215/6218 to
take measurements on all AI channels when all channels share a common
ground. Refer to Figure 6-2 for an illustration of an RSE connection
configuration.

Note If you leave the AI GND pin unconnected, the signals will float outside the working
input range of the USB-6215/6218, which may result in unreliable measurements because
there is no way to ensure that the input signal is within 10 V of AI GND.

Figure 6-2. Connecting a Device to a USB-6215/6218 Using RSE Connections

In an RSE connection configuration, each input channel is measured with
respect to AI GND.

AI1

AI2

AI GND

USB-6215/6218

MUX

ADC

PGIA