Table 31. ni 9217 calibration coefficients, Ni 9219, Table 32. ni 9219 vendor configuration extensions – National Instruments Deterministic Ethernet Expansion Chassis NI 9144 User Manual

Page 38

Advertising
background image

NI 9144 User Guide and Specifications

38

ni.com

Note

LSB weight is referred to as Gain in the object dictionary.

The calibration data is stored in a U32 array, though each Offset field
(subindex 1, 3, 5, and so on) should be interpreted as a signed value.

Use the calibration coefficients with the following equation to generate
correct data:

R

raw

(bits) = data returned by the NI 9217 in bits

R

corrected

= calibrated resistance reading

NI 9219

Table 31. NI 9217 Calibration Coefficients

Coefficient

Representation

Units

LSB Weight

Unsigned

p

Ω/LSB

Offset

Signed

μΩ

Table 32. NI 9219 Vendor Configuration Extensions

Index

Sub

Type

R/W

Description

0x2001

0

ARR:U32

Command List = 33

1

R

Command Count = 1..32, default = 32

2..33

R/W

Configuration Command

0x2002

1

ARR:U32

R

Error Status

0x2005

0

U32

R/W

ADC Format

R

corrected

R

raw

(

)

R

raw

bits

(

)∗ LSB

weight

p

Ω

bits

---------

⎞∗10

12

Ω

p

Ω

-------

Offset

μΩ

(

)∗10

6

Ω

μΩ

--------

=

Advertising