Chapter 4

Analog Input

NI 6124/6154 User Manual

4-6

ni.com

Analog Input Triggering

Analog input supports two different triggering actions: start and reference.
An analog or digital hardware trigger can initiate these actions. All S Series
devices support digital triggering, and some also support analog triggering.
To find your device’s triggering options, refer to the specifications
document for your device.

The

AI Start Trigger Signal

and

AI Reference Trigger Signal

sections

contain information about the analog input trigger signals.

Refer to Chapter 11,

Triggering

, for more information about triggers.

Connecting Analog Input Signals

Table 4-1 summarizes the recommended input configuration for different
types of signal sources for S Series devices.

Table 4-1. S Series Analog Input Signal Configuration

Input

Floating Signal Sources

(Not Connected to Earth Ground)

Ground-Referenced Signal Sources

Examples:

• Ungrounded thermocouples

• Signal conditioning with isolated

outputs

• Battery devices

Example:

• Plug-in instruments with

non-isolated outputs

NI 6124
Non-Isolated
Differential
(DIFF)

NI 6154
Isolated
Differential
(DIFF)

AI 0+

AI 0–

AI GND

V

1

+

+

R

V

1

AI 0+

AI 0–

AI GND

+

+

AI+

A I–

Isolation

Barrier

+

+

AI+

AI–

Isolation

Barrier

+

+