Chapter 18 Classifier

GS-4012F/4024 User’s Guide

153

Ethernet
Type

Select an Ethernet type or select Other and enter the Ethernet type number in
hexadecimal value. Refer to

Table 44 on page 154

for information.

Source

MAC
Address

Select Any to apply the rule to all MAC addresses.
To specify a source, select the second choice and type a MAC address in valid MAC
address format (six hexadecimal character pairs).

Port

Type the port number to which the rule should be applied. You may choose one port only
or all ports (Any).

Destination

MAC
Address

Select Any to apply the rule to all MAC addresses.
To specify a destination, select the second choice and type a MAC address in valid MAC
address format (six hexadecimal character pairs).

Layer 3
Specify the fields below to configure a layer 3 classifier.

DSCP

Select Any to classify traffic from any DSCP or select the second option and specify a
DSCP (DiffServ Code Point) number between 0 and 63 in the field provided.

IP
Protocol

Select an IP protocol type or select Other and enter the protocol number in decimal value.
Refer to

Table 45 on page 155

for more information.

You may select Establish Only for TCP protocol type. This means that the Switch will pick
out the packets that are sent to establish TCP connections.

Source

IP
Address/
Address
Prefix

Enter a source IP address in dotted decimal notation.
Specify the address prefix by entering the number of ones in the subnet mask.

Socket
Number

Note: You must select either UDP or TCP in the IP Protocol field before

you configure the socket numbers.

Select Any to apply the rule to all TCP/UDP protocol port numbers or select the second
option and enter a TCP/UDP protocol port number.

Destination

IP
Address/
Address
Prefix

Enter a destination IP address in dotted decimal notation.
Specify the address prefix by entering the number of ones in the subnet mask.

Socket
Number

Note: You must select either UDP or TCP in the IP Protocol field before

you configure the socket numbers.

Select Any to apply the rule to all TCP/UDP protocol port numbers or select the second
option and enter a TCP/UDP protocol port number.

Add

Click Add to insert the entry in the summary table below and save your changes to the
Switch’s run-time memory. The Switch loses these changes if it is turned off or loses
power, so use the Save link on the top navigation panel to save your changes to the non-
volatile memory when you are done configuring.

Cancel

Click Cancel to reset the fields back to your previous configuration.

Clear

Click Clear to set the above fields back to the factory defaults.