Chapter 36 Access Control

GS-4012F/4024 User’s Guide

292

Figure 176 Access Control: SNMP

The following table describes the labels in this screen.

Table 118 Access Control: SNMP

LABEL

DESCRIPTION

General Setting

Use this section to specify the SNMP version and community (password) values.

Version

Select the SNMP version for the Switch. The SNMP version on the Switch must
match the version on the SNMP manager. Choose SNMP version 2c (v2c), SNMP
version 3 (v3) or both (v3v2c).

Note: SNMP version 2c is backwards compatible with SNMP

version 1.

Get Community

Enter the Get Community string, which is the password for the incoming Get- and
GetNext- requests from the management station.
The Get Community string is only used by SNMP managers using SNMP version
2c or lower.

Set Community

Enter the Set Community, which is the password for incoming Set- requests from
the management station.
The Set Community string is only used by SNMP managers using SNMP version
2c or lower.

Trap Community

Enter the Trap Community string, which is the password sent with each trap to
the SNMP manager.
The Trap Community string is only used by SNMP managers using SNMP
version 2c or lower.

Trap Destination

Use this section to configure where to send SNMP traps from the Switch.

Version

Specify the version of the SNMP trap messages.

IP

Enter the IP addresses of up to four managers to send your SNMP traps to.

Advertising