Communica tion with pc – Yamaha SRCP User Manual

Page 198

Advertising
background image

11-

22

11

COMMUNICA

TION WITH PC

11-5 Communication Command Description

(20-1) @?PRM <parameter number>

Reads the data from a specified parameter.

Parameter number

: This is a number used to identify each parameter and can be from

0 to 99.

Transmission example

: @?PRMl c/r l/f ............................. Reads the data from PRM1

(parameter 1).

Response example 1

: 350 c/r l/f

OK c/r l/f

Response example 2

: c/r l/f ............................................. No data is registered in PRM1

(parameter 1).

OK c/r l/f

(20-2) @?PRM <parameter number>,<parameter number>

Reads multiple parameter data from the first parameter number to the second parameter number.
If unregistered parameters exist, they will be skipped.

Parameter number

: This is a number used to identify each parameter and can be from

0 to 99.

Transmission example

: @?PRMl,5 c/r l/f .......................... Reads the data from PRM1 to

PRM5 (parameters 1 to 5).

Response example

: PRM1=350 c/r l/f

PRM2=0 c/r l/f
PRM3=3 c/r l/f
PRM4=100 c/r l/f
PRM5=0 c/r l/f
OK c/r l/f

(21-1) @?P <point number>

Reads the data of a specified point.

Point number

: This is a number used to identify each point data and can be from

0 to 999.

Transmission example

: @?P 254 c/r l/f ............................. Reads the data of point 254.

Response example 1

: -0.05 c/r l/f

OK c/r l/f

Response example 2

: c/r l/f ............................................. No data is registered in the

specified point.

OK c/r l/f

Advertising