User line connector, User line wiring, User line connection – Xantrex Technology XDI2048 User Manual

Page 32: Table 2-1, User line connection –12

Advertising
background image

Rack Mount Frame Assembly and Installation

2-12

TM-DIOP-01XN-01

User Line Connector

The user-line is a 6-position wire clamp connector adjacent to the DC
input connector. Table 2-1 lists user functions and associated terminal
numbers.

User Line Wiring

Use twisted pairs of 22-24 AWG for connections. Before making any
connections, ensure power to the rack has been disconnected. Carefully
route the wires away from high power load cables to minimize noise
effects on signal integrity.

User Line Connection

Use this table to wire appropriate signals.

User line voltages are below:

Table 2-1 User Line Connection

Terminal

Label

I/O

Logic Level

Function

1

User line return

GND

GND

GND reference

2

User shutdown

Input

Active high

Shuts down
inverter

3

Fault Flags

Output

Active high

Inverter faults

4

AUX flag

Output

N/A

User configurable

5

Inverter flag

Output

Active high

Inverter on-line

6

Not used

N/A

N/A

N/A

Inputs

High
Low

1.25 V to 5 V
0.0 V to 1.25 V

Outputs

High
Low

5 V
1.5 V max.

Advertising