AC Load and Signal Line Connection

TM-DIOP-01XN-01

2-13

CAN/SYNC Connector

Overview

The CAN/SYNC connector provides access to functions necessary for
operation of multiple units in parallel, series or three phase. The
connector is a 7-position wire clamp adjacent to the user-line. Two sets of
signals are provided on this connector:

Can-bus: Paralleled units relay data necessary to achieve load sharing
between units using this arbitration bus. The protocol used is
proprietary hence cannot be and should not be interfaced to different
products.

Sync-lines: Used to configure and synchronize units in parallel, series
or 3 phase.

Specifications:

CAN/SYNC Connection

Table 2-2 outlines the pinout of the terminal. See connection schemes for
wiring method applicable to your requirements.

Maximum number of units

10

Bus Speed

1 Mb/sec

Termination

120

Ω 1/4 W

Addresses

1 to 10