The user can enter the handset’s number or IPEI. At least one parameter has
to be set. The entered number or IPEI has to match exactly with a handset’s
number or IPEI. If number and IPEI are given then a handset has to exist in
the OMM’s database whose number and IPEI match both otherwise the
search fails.

If a handset with the specified number and/or IPEI was found then a list is
displayed which has this handset as the first entry. The search function can
also be used to get to the right sub list in one step.

3.3.5

WLAN Configuration (RFP L42 WLAN only)

The correct configuration of a RFP with a WLAN part requires the correct
configuration of the DECT part. The second step is to specify the regulatory
domain of the WLAN network at the system web page of the OMM web
service.

Regulatory Domain

Country

0x10: FCC

USA, Australia

0x20: IC

Canada

0x30: ETSI

Europe (excluding Spain, France)

0x31: SPAIN

Spain

0x32: FRANCE

France

0x40: MKK

Japan

0x41: MKK1

Japan

(MKK1)

This setting depends on the country and is prescribed by the laws of that
country. Only the setting prescribed for that country must be used.