VEGA INSYS Modem GPRS 5.0 User Manual

Page 15

Advertising
background image

INSYS GPRS 5.0 serial

Mounting

15

4.5.1 Installation

Caution - Electric shock hazard

Do not touch live parts when connecting the device.

Make sure that the power supply of the switch board or the system
where the device will be installed is switched off during installation,
and that it is secured against being switched on accidentally.

This section applies only to the initial startup of the device with factory settings.

1.

Have the SIM card and the according PIN ready.

2.

Install the device on a DIN rail.

3.

Connect the power supply.

First, connect the ground connection.

4.

Connect a suitable power supply (10..60V DC).

Note: The minimum supply voltage value is 10V DC. The maxi-
mum supply voltage value is 60V DC.

5.

Connect the antenna.

Use a suitable GSM antenna.

You can obtain suitable GSM antennas as accessories for this
device from INSYS.

6.

Switch the power supply on.

The power LED will light up.

7.

Wait until the device has powered up.

The status LED blinks during the boot process.

The signal LED blinks when the process is completed.

Advertising