VEGA INSYS Modem GPRS 5.0 User Manual

Page 33

Advertising
background image

INSYS GPRS 5.0 serial

Connection

33

Mark and then apply the selection.

Alternatively, the settings can be entered or modified using the terminal pro-
gram.

Enter PIN

AT**PIN

If manual network provider selection is
required, the network provider identifi-
cation number must be determined. You
will find a chart for the INSYS GPRS 5.0
serial with identification numbers and
names in the AT command overview –
available at no charge from INSYS. In
our example, the German network T-
Mobile with the identification number
26201 is used.

Network provider selection for T-Mobile
in Germany

AT**PROVIDER=2,1,26201

Perform a RESET to use the PIN.

AT**RESET

Manual registration after each reset

If the module is started and logged in from an external application, this applica-

tion may request a manual login. In this case, the following method should be
used:

Enter the PIN (when the PIN is entered via

this command, it must be re-entered for
each reset).

AT+CPIN=<PIN>

Prompt manual registering (this command

may trigger a waiting period of several sec-
onds)

AT+COPS=0

Advertising