89

Multislot class

Downlink slots

Uplink slots

Active slots

8

4 TS

1 TS

5 TS

9

3 TS

2 TS

5 TS

10

4 TS

2 TS

5 TS

11

4 TS

3 TS

5 TS

12

4 TS

4 TS

5 TS

The maximum possible data rate therefore depends on the multislot class of the
device. The above table shows the available time slots (TS) of a device; the table
below shows the maximum data rate. The data rate, on the other hand, depends
on the used coding scheme (CS). This information is unfortunately not available
for the user. The network providers use different coding schemes according to the
reception situation.

1 TS

2 TS

3 TS

4 TS

CS1

9,05

18,1

27,15

36,2

CS2

13,4

26,8

40,2

53,6

CS3

15,6

31,2

46,8

62,4

CS4

21,4

42,8

64,2

85,6

Data rates of PC data including GPRS control data

1 TS

2 TS

3 TS

4 TS

CS1

8

16

24

32

CS2

12

24

36

48

CS3

14,4

28,8

43,2

57,6

CS4

20

40

60

80

Data rates of PC data only (without GPRS control data)

Note: The above mentioned values represent the theoretically maximum possible

values.

In practice, the following applies:
GPRS will not provide guaranteed data rates or bandwidths for the application.
The values allocated by the network provider (coding scheme and time slots to be
used) can change dynamically during a connection and, among other things, de-
pend on the current amount of connections in the GSM cell.

In the device class B, the INSYS GPRS 5.0 serial supports the GSM services GPRS,
CSD and voice. However, only one service can be executed at a time.