Connection

INSYS GPRS 5.0 serial

40

Alternatively, the settings for TCP Listen can be entered using the terminal pro-
gram.

Automatic Connection acceptance

ATS0=2

Save this setting

AT&W

Set the TCP data port

AT**TCPLISTENPORT=1234

Activate TCP Listen

AT**TCPLISTEN=1

Save settings

AT**SAVE

Perform RESET,
accept all parameters

AT**RESET


The successful dial-up into the GPRS network is displayed after the startup with
the message +PPP-IP SETUP; the INSYS INSYS GPRS 5.0 serial can now be reached
via its IP address.

If the connection can not be established (network failure, etc.) or if the connection
is terminated, the INSYS GPRS 5.0 serial will automatically start reconnecting.

To limit the connection costs for failed connection setups (for each connection
setup data packets are created and billed), the delay time will increase for every
new repeated attempt.

20 seconds after restart or if the last connection setup was successful

80 seconds after the first failure

320 seconds after the second failure

1280 seconds after the third failure

1 hour for each additional failure