4 technical data, 1 supply, 2 rs-232 interface – VEGA Phoenix PSI Data Fax Modem User Manual

Page 16: Technical data -6, Supply -6, Rs-232 interface -6

Advertising
background image

PSI-DATA/FAX-MODEM/RS232

1-6

692302

1.4

Technical Data

1.4.1

Supply

Supply voltage

Frequency

Current Consumption

- Nominal operation
- Sleep mode (configurable via software)

Indicator

10 V to 60 V DC or 16 V to 40 V AC via plug-in
COMBICON screw terminal block

DC or 50 Hz to 60 Hz

< 100 mA (at 24 V)
< 40 mA (at 24 V)

Green LED (VCC), steady light during operation,
flashes in sleep mode

1.4.2

RS-232 Interface

Connection

Device type

Data format/encoding

Data flow check/protocol

Serial transmission rate

LED data indicator

Control signal indicator

9-pos. D-SUB male connector

DCE

Serial asynchronous UART/NRZ, 7/8 data, 1/2 stop,
1 parity, 10/11-bit character length

Software handshake Xon/Xoff, direct mode, hardware
handshake RTS/CTS or 3964R

Automatic data rate detection (default) or fixed setting
at 300, 1200, 2400, 4800, 9600, 19200, 38400, 57600,
115200 bps, adjustable via software

Green LED (TD)/yellow LED (RD), transmit/receive
data with reference to PSTN port, dynamic

Yellow LED DTR (Data Terminal Ready)
Yellow LED DCD (Carrier Detect)