PSI-DATA/FAX-MODEM/RS232 Industrial Modem

692302

1-7

1.4.3

PSTN Port (a/b Line)

Connection

Shield

Operating modes

Dial-up method

Transmission rate
- DCE/DCE
- Fax

Compatibility

Fax compatibility

Instruction set compatibility

Error correction

Data compression

RJ-12, 6-pos. or plug-in COMBICON screw terminal
block

DC coupled on DIN rail

Dial-up modem, 2-wire half/full duplex
Fax modem, 2-wire half duplex
Permanent line, 2-wire full duplex

Multi-frequency/pulse dial configurable via software

Automatic adjustment according to V.8
300 baud to 33.6 kbaud
2400 baud to 14.4 kbaud

ITU V.42bis, V.42, V.34 extended, ITU V.32bis, V.32,
V.21, V.22bis, V.22, V.23, Bell 212A, and 103,
ITU V.17, Group 3 T.4, T.30, and EIA TR-29

EIA TR-29 Class 2, CCITT V.17, Group 3, V.29, V27ter

AT standard instruction set and extended, V.250 basic
instruction set

V.42 (LAP-M or MNP 2 to 4)

V.42bis (throughput 4:1), MNP 5 (throughput 2:1)

LED data indicator

Audible signaling

Operating diagnostics

Adaptive cable test

Telecommunications approvals

Hardware settings

Green LED (OH), off the hook

Yellow LED (AA), automatic answer (automatic call
acceptance), flashes during selective acceptance of
calls

Yellow LED (FAX) fax mode active

Yellow LED (EC) error correction in V.42 mode, flashes
when data compression is active

Integrated piezo

Power on selftest, visualization via LEDs (controller,
SRAM, EEPROM, DSP)

Dial tone test, pulse dial ring test via additional function
in configuration software

TBR21, TBR15, TIA/EIA/IS-968
for Europe, USA, and Canada

4-way DIP for dial-up and permanent line operation
(under removable cover)