VEGA Phoenix PSI Data Fax Modem User Manual

Page 75

Advertising
background image

Special Functions

692302

5-5

The number and the password for the partner must be entered for the OUT
configuration. The option can be set to "0" or "1":

Example for OUT

NUMBER <;>PASSWORD<;>OPTION<^Z>: 040999888777;QWERT;0^Z

AT*A1? command

The AT*A1? command can be used to view the specified configuration again.

Examples

AT*A1?<CR>
CONFIG INPUT 1
SMS (Y/N) Y
FAX (Y/N) Y
OUT (Y/N) Y

SMS (SMS function):

NUMBER <CR>TEXT…<^Z>: 0160123456789<CRLF>Alarm at input 1 pump
failure

FAX (fax function):

NUMBER <CR>TEXT…<^Z>: 040999888777;<CRLF>
JohnDoe<CRLF>
615N10thStreet<CRLF>
RichmondVA12345-0123<CRLF>
<CRLF>
ALARM MESSAGE
<CRLF>
Heating failure - pump faulty <CRLF>

OUT (set partner output):

NUMBER <CR>PASSWORD:01291212<CRLF>
QWERT<CRLF>
OPTION:0<CRLF>

When AT*A1?<CR> messages are requested, <CR> is replaced with <CRLF> in
the text. This improves the message display in a terminal program.

Option 0

Set

The partner output is set by activating the local input

Option 1

Follow

The partner output follows the local input. A new call must be made
each time the input changes. Sleep/Power Down mode is disabled in
this mode.