Switching Input and Output

Switching input

U

Nom

24 V DC/5 mA, input range 9...48 V DC,

electrically isolated.

Activates one or more of the following:

A message on the local RS-232

An SMS (only in dial-up operation)

A fax (only in dial-up operation)

Output control at the opposite station

Switching output

Miniature switching relay 60 V/1 A, N/O contact,
activated by:

Input control at the opposite station

An SMS (only in dial-up line operation)

A local AT command

An AT command at the opposite station

Signaling

Red LED (ALR), flashes when an SMS/FAX error
message is to be sent,
Steady light when alarm has been triggered

Red LED (ERR), if alarm cannot be triggered

Reset (acknowledgment) through:

SMS (remote)

AT command (local + remote)

Pushbutton (local)

1.4.5

Text and Telephone Number Memory

Text memory

SMS
Fax

Telephone number memory

160 characters
253 characters, 30 kbytes

20 telephone numbers with a maximum of 36 digits