3 control via sms messages, Control via sms messages -16 – VEGA Phoenix PSI Data Fax Modem User Manual

Page 86

Advertising
background image

PSI-DATA/FAX-MODEM/RS232

5-16

692302

5.7.3

Control via SMS Messages

The PSI-DATA/FAX-MODEM/RS232 can be controlled via SMS messages. For
example, you can activate the output, reset the alarm or send the status of the
modem simply by sending an SMS message.

This mode is activated using the AT\S2 command. In this mode, the SMS message
is not forwarded to the termination equipment, but is evaluated by the modem itself.
The SMS message sent to the modem must be structured as follows:

#<Password>:<Command>

The password (AT*P=) is the password stored in the modem (maximum of seven
characters). Please note that not all characters can be sent in the SMS message.
Choose a password according to the SMS character set. If the password is set,
e.g., to AT*P=12345 the message should appear as follows:

#12345:<Command>

The following control commands are available:

RESET

Resets the alarm and the switching output
(e.g., AT*AR).

SET:OUTPUT

Activates the switching output ("Output").

CLR:OUTPUT

Deactivates the switching output ("Output").

SEND:STATUS

Sends a status SMS message to the caller.

"Text"

Outputs all the characters within the inverted commas
to the RS-232 interface.

Examples

#12345:SET:OUTPUT

Activates the output.

#12345:SEND:STATUS

Sends an SMS message (status report) to the sender.

#12345:"RST PLC"

Sends the text RST PLC to the terminal equipment
(RS-232 interface).

#12345:RESET

Resets the alarm function and the switching output.