2 alarm inputs and alarms, Alarm inputs and alarms -4, 2 alarm inputs and alarms – VEGA Phoenix PSI Data Fax Modem User Manual

Page 74

Advertising
background image

PSI-DATA/FAX-MODEM/RS232

5-4

692302

5.2

Alarm Inputs and Alarms

The PSI-DATA/FAX-MODEM/RS232 modem has one electrically isolated input
and one electrically isolated output. Alarm functions can be assigned to the input,
i.e., SMS and/or fax messages can be automatically sent by activating the input
and/or the output of a partner can be activated.

The control system is configured using AT commands (see Section
"AT Commands" on page 6-3
).

Configuring the Input

Command: AT*A1<CR>

Configure the modem via the following menu items:

CONFIG INPUT 1
SMS (Y/N) Y
FAX (Y/N) Y
OUT (Y/N) Y

If you activate the SMS function with Y, you are prompted to enter the destination
number and the text (160 characters maximum) for the SMS message. End the text
entry with ^Z (Ctrl+Z).

Example for an SMS

NUMBER <;>TEXT…<^Z>: 0160123456789;Alarm at input 1 pump failure^Z

If you do not wish to send an SMS or fax message during configuration, enter N.
You then do not have the option of entering the SMS or fax message.
Press "ESC" to cancel an entry. This may take a moment, as all messages have to
be reformatted and then saved.

The number must end with ;. In the fax text, <CR> is the code for a line break, the
ASC text is exited via Ctrl+Z. The maximum line length of 60 characters must not
be exceeded.

Example for a fax

NUMBER <;>TEXT…<^Z>: 040999888777;<CR>
JohnDoe<CR>
615N10thStreet<CR>
RichmondVA12345-0123<CR>
<CR>
ALARM MESSAGE
<CR>
Heating failure - pump faulty <^Z>