4 supply voltage, 5 switching input, 6 switching output – VEGA Phoenix PSI Data Fax Modem User Manual

Page 45: Supply voltage -13, Switching input -13, Switching output -13

Advertising
background image

Hardware Installation

692302

3-13

3.3.4

Supply Voltage

The supply voltage must be within the range of 10 V to 60 V DC or 16 V to 40 V AC
(50 - 60 Hz).

Connect the 24 V voltage supply to the "24V" and "0V" connection points on the
plug-in screw terminal block.

Figure 3-9

Connections

As soon as the "VCC" LED lights up, the modem is ready.

3.3.5

Switching Input

3.3.6

Switching Output

The switching output is a floating form A contact and is designed for 60 V/1 A. The
contact is connected to the plug-in screw terminal block marked with the form A
contact symbol (see Figure 3-9).

The PSI-DATA/FAX-MODEM/RS232 module is designed exclusively for SELV
operation according to IEC 60950/EN 60950/VDE 0805.

Table 3-3

Switching input on the plug-in screw terminal block

Connection

Meaning

i+ (floating)

9 V to 48 V DC

i–

0 V

n . c . a b

2 4 V 0 V n . c . n . c .

i + i -

6 9 2 3 A 0 3 8

2 4 V

0 V

Advertising