Assemble – Grain Systems Tanks PNEG-4060 User Manual

Page 114

Advertising
background image

Chapter 7: Roof Assembly

Figure 7-30 Installation of remaining roof flashing sections

A

Roof flashing (CTR-0185)

C

5/16 in. flange nut (S-3611)

B

5/16-18 x 1 flange bolt with sealing washer
(S-10260)

D

Rope caulk

After You Finish

NOTE: If roof exhausters will be installed, see roof accessories,

Preparation for Roof Exhauster Installa-

tion, page

.

Assemble and Install Center Collar Channels and Cap Plates

The following procedure is for assembling the center collar channels and cap plates on the ground, and lift-
ing the entire assembly as one unit.

1. Locate a short center collar channel (F), and install a short channel clip (D) to the outer edge of the

short center collar channel (F).

2. Install flange bolts (C) and flange nuts (E), and repeat this procedure for the opposite end of this

short center collar channel (F).

3. Install one 3/8 in. bolt (B) and nut (A) into the center hole of the short center collar channel (F) to aid

with water shedding,

NOTE: Installing the 3/8 in. bolt (B) and nut (A) will create a slight pitch when the center cap plate is

installed, allowing water to shed from this area.

4. Locate the second short center collar channel (F), and repeat this procedure.

5. Place both assembled short collar channels (F) aside to use later in this procedure.

114

Pneg-4060 60 Ft Diameter 40-Series Bin

Advertising