Stiffeners splice, Chapter 6: stiffeners – Grain Systems Tanks PNEG-4060 User Manual

Page 55

Advertising
background image

Chapter 6: Stiffeners

Stiffeners Splice

Use the following information to determine the gauge of the splice needed to connect the stiffeners.

Figure 6-3 Stiffener splice

Call Out

Part Number

Description

Length

Available Gauges

A

CTS–2091XX

Stiffener splice

10 in. (25.4 cm)

8, 10, 12, 14

Use the following chart to determine the gauge of the splice, which is determined by the gauge of the stiff-
eners that are being connected. If connecting a heavier gauge to a lighter gauge stiffener, always use the
heavier gauge splice for the 13 to 12, 8 to 6, and 2 to 0 gauge connections.

For example: If connecting a 13 gauge stiffener to a 12 gauge stiffener, use the 12 gauge splice. If con-
necting an 8 gauge stiffener to a 6 gauge stiffener, use the 10 gauge splice. If connecting a 2 gauge stiff-
ener to a 0 gauge stiffener, use the 8 gauge splice.

Table 6-3 Splice Usage

Stiffener Gauge

Splice Gauge

8 Gauge

10 Gauge

12 Gauge

14 Gauge

18

X

17

X

16

X

15

X

14

X

13

X

12

X

11

X

10

X

9

X

8

X

6

X

5

X

2

X

0

X

Pneg-4060 60 Ft Diameter 40-Series Bin

55

Advertising