Chapter 8: accessories – Grain Systems Tanks PNEG-4060 User Manual

Page 157

Advertising
background image

Chapter 8: Accessories

Figure 8-25 Discharge chute assembly (view form inside the bin)

H

Discharge chute assembly

J

Lower sidewall panel

I

Upper sidewall panel

12.Using the discharge chute assembly (H) as a guide or template, field drill all necessary holes to

secure the discharge chute assembly (H) to the upper sidewall panel (I) and the lower sidewall panel
(J).

NOTE: When using the discharge chute assembly (H) as a guide or template, field drilling the upper

sidewall panel (I) will be done from inside the bin structure, and field drilling the lower sidewall
panel (J) will be done from outside the bin structure.

13.Install flange bolts (K) and flange nuts (L), securing the discharge chute assembly (H) to the upper

sidewall panel (I) and the lower sidewall panel (J).

Pneg-4060 60 Ft Diameter 40-Series Bin

157

Advertising