Chapter 8: accessories – Grain Systems Tanks PNEG-4060 User Manual

Page 131

Advertising
background image

Chapter 8: Accessories

Figure 8-6 Using the roof exhauster flashing and mounting plate as a template

E

5/16 in. flange nut (S-3611)

K

Roof panel

F

Exhauster mounting plate

I

Marked or scribed hole to be cut

G

5/16 x 1 in hex bolt (S-10260)

J

Field bent inside tab on roof exhauster mounting
plate

H

Holes to be field drilled

4. Bend the tabs (J) downward approximately 90 degrees on the roof exhauster mounting plate (F) to

conform with the roof panel.

NOTE: Bend the tabs on the ground and adjust as necessary once on the roof.

5. Remove the roof exhauster mounting plate (F), to make the necessary cut along the mark or scribe

(I).

Pneg-4060 60 Ft Diameter 40-Series Bin

131

Advertising