Chapter 6: stiffeners – Grain Systems Tanks PNEG-4060 User Manual

Page 58

Advertising
background image

Chapter 6: Stiffeners

Close-Punch Connection for a One-Ring Top Stiffener (16 Ga) and a
Two-Ring Stiffener (16 Ga)

Reference the following information for a close-punch connection of a one-ring top stiffener (CTS-2118XX)
to a two-ring stiffener (CTS-2075XX).

Figure 6-6 One-Ring Top Stiffener (16 Ga) and a Two-Ring Stiffener (16 Ga) Close-Punch Connection

A

One-ring top stiffener (CTS-2118XX)

B

Two-ring stiffener (CTS-2075XX)

C

Splice (CTS-2091XX)

D

3/8 x 1 Bolt (S-7485)

E

3/8 Nut (S-9426)

F

Completed assembly

NOTE: Two-post stiffeners shown. The bolt pattern will

vary for three-post. Only place bolts where
holes in the stiffeners align with holes in the
sidewall sheet.

Two-Ring Top Stiffener to a Two-Ring Stiffener (15–16 Ga)
Connection

Reference the following information when connecting a two-ring top stiffener (CTS-2111XX) to a two-ring
stiffener (CTS-2064XX).

Figure 6-7 Two-Ring Top Stiffener to a Two-Ring Stiffener (15–16 Ga) Connection

A

Two-ring top stiffener (CTS-2111XX)

B

Two-ring stiffener (CTS-2064XX)

C

Splice (CTS-2091XX)

D

3/8 x 1 Bolt (S-7485)

E

3/8 Nut (S-9426)

F

Completed assembly

NOTE: Two-post stiffeners shown. The bolt pattern will

vary for three-post. Only place bolts where
holes in the stiffeners align with holes in the
sidewall sheet.