14 ga), Chapter 6: stiffeners – Grain Systems Tanks PNEG-4060 User Manual
Page 65
Close-Punch Two-Ring Stiffener (2–14 Ga) to a Laminated Stiffener
(2 Ga) with an Insert (10–14 Ga)
Reference the following information for a close-punch connection with a two-ring stiffener (CTS-2073XX)
to a laminated stiffener (CTS-2114XX) and insert (CTS-2113XX).
Figure 6-19 Close-Punch Two-Ring Stiffener to a Laminated Stiffener with an Insert
A
Close-punch two-ring stiffener (CTS-2073XX)
B
Close-punch laminated stiffener
(CTS-2114XX)
C
Insert (CTS-2113XX)
D
3/8 x 1 Bolt (S-7485)
E
3/8 Nut (S-9426)
F
Completed assembly
NOTE: Two-post stiffeners shown. The bolt pattern will
vary for three-post. Only place bolts where
holes in the stiffeners align with holes in the
sidewall sheet.
Close-Punch Laminated Stiffeners (2 Ga) with Inserts (10–14 Ga)
Reference the following information for a close-punch connection of a laminated stiffener (CTS-2079XX) to
a laminated stiffener (CTS-2081XX).
Figure 6-20 Close-Punch Laminated Stiffeners with Inserts
A
Close-punch laminated stiffener
(CTS-2079XX)
B
Close-punch insert (CTS-2081XX)
C
3/8 x 1 Bolt (S-7485)
D
3/8 Nut (S-9426)
E
Completed assembly
NOTE: Two-post stiffeners shown. The bolt pattern will
vary for three-post. Only place bolts where
holes in the stiffeners align with holes in the
sidewall sheet.
Pneg-4060 60 Ft Diameter 40-Series Bin
65