Chapter 6: stiffeners – Grain Systems Tanks PNEG-4060 User Manual

Page 59

Advertising
background image

Chapter 6: Stiffeners

Close-Punch Connection for a Two-Ring Top Stiffener to a Two-Ring
Stiffener (16 Ga)

Reference the following information for a close-punch connection of a two-ring top stiffener (CTS-2116XX)
to a two-ring stiffener (CTS-2075XX).

Figure 6-8 Two-Ring Top Stiffener to a Two-Ring Stiffener (16 Ga) Close-Punch Connection

A

Two-ring top stiffener (CTS-2116XX)

B

Two-ring stiffener (CTS-2075XX)

C

Splice (CTS-2091XX)

D

3/8 x 1 Bolt (S-7485)

E

3/8 Nut (S-9426)

F

Completed assembly

NOTE: Two-post stiffeners shown. The bolt pattern will

vary for three-post. Only place bolts where
holes in the stiffeners align with holes in the
sidewall sheet.

Two-Ring Stiffener (15-16 Ga) to a Two-Ring Stiffener (15–16 Ga)
Connection

Reference the following information when connecting a two-ring stiffener (CTS-2064XX) to a two-ring stiff-
ener (CTS-2064XX).

Figure 6-9 Two-Ring Stiffener (15-16 Ga) to a Two-Ring Stiffener (15–16 Ga) Connection

A

Two-ring stiffener (CTS-2064XX)

B

Two-ring stiffener (CTS-2064XX)

C

Splice (CTS-2091XX)

D

3/8 x 1 Bolt (S-7485)

E

3/8 Nut (S-9426)

F

Completed assembly

NOTE: Two-post stiffeners shown. The bolt pattern will

vary for three-post. Only place bolts where
holes in the stiffeners align with holes in the
sidewall sheet.

Pneg-4060 60 Ft Diameter 40-Series Bin

59

Advertising