Daily inspection, Ordering correct replacement units or parts, Storage and operation after storage – Grain Systems PNEG-526 User Manual

Page 153

Advertising
background image

DAILY INSPECTION

1. Visually check the oil level gauge on the vertical
unit, forced-lubricated type. Check lubrication

by

viewing piping set and oil signal (Part No. 41). Faulty
operation is caused by a lack of lubrication oil,
damage to the plunger pump (Part No. 42) or the
positive displacement pump (Part No. 43) or the

clogging of pipes, etc. In case of faulty operation, stop

and inspect the unit immediately.

2.

A temperature rise of approximately 105°F

above ambient on the surface of the ring gear housing
(Part No. 2-01) is allowable if the temperature

fluctuation is

If temperature rises rapidly from a

stable condition, add the recommended oil or grease

(Tables A-7 and

A rapid temperature rise may

be caused from a lack of lubrication.

If after lubricating unit, the problem persists, stop
operation and consult

3. When an abnormal sound is heard from inside the
unit, stop operation and inspect the unit.

4. If the lubrication oil leaks, replace the damaged or
worn part with a new one. (Refer to Part No.
Page A-3.)

Ordering Correct Replacement Units Or Parts

The

is fully standardized to offer maximum

Name Plate on

part interchangeability among models of the same frame

I

size. However, there are many frame sizes, models and
types in the production range of SM-CYCLO? Therefore
to get correct replacement units or parts, proper

information to identifv the

reducer in auestion is

i

CHESAPEAKE,

Storage And Operation After Storage

essential. The

is secured'to the body

of the drive, provides this identifying data.

Please give the full description shown on the name plate
to your distributor. Be sure to include the

NUMBER and MODEL NUMBER. This information,
along with our production records, will enable us to
provide you with the correct replacement unit or parts.

Storage 6 Months-1 Year

Oil-Lubricated

RATIO

SERVICE FACTOR

HP

RPM

OUTPUT TORQUE

IN-LB

SERIAL NO.

1. Completely fill

with a rust-preventive oil

or equivalent) or a circulating oil (Shell VSI No.

100 or equivalent).

2. At approximately

3

month intervals, rotate the input

shaft a sufficient number of times to insure all internal
components remain coated. (The higher the ratio, the
greater the amount of rotations needed for proper
lubrication.)

Grease-Lubricated

Grease-lubricated models do not require any special
attention during storage. (Inspect unit before
operation.)

Operation After Storage 6 Months-1 Year

Oil-Lubricated

1. Completely drain the rust preventive, or circulating
oil from unit.

2.

Flush unit with the recommended operating oil as

shown in Table

1.

3.

After flushing, fill the unit to the proper oil level with

the recommended lubricating oil.

Grease-Lubricated

Add

the recommended quantity of new grease as

shown in Table A-10.

Note: Consult the factory before operating units stored
for periods greater than

1

year.

Note: For both the Oil-Lubricatedand

Lubricated models, if units are to be stored for a

period exceeding 1 year, consult factory.