Tower Dryer Operations & Service

II. Set-Up of the Controller

6

5

4

1

2

3

*Press the “MOIST CONTROL” button from the main screen to access the moisture set-up

screen:

1.

Unload upper limit - the maximum

unloading rate (%) in which dryer can be
run without plugging any unloading con-
veyors.

2.

Current column grain tempera-

ture - measured from the RTD sensor at
the end of the drying section (it is not the
temperatureof the grain coming out of the
dryer).

3.

Unload lower limit - the minimum

unloading speed that can maintain the sam-
pling box of the dry sensor full of grain. It
is essential to have the sensor fully covered

4.

Calibration button - to access

sensor calibration screen (see Section III,
Step 3).

5.

Control Mode button - toggle the

control mode between MANUAL and
AUTO by pressing the button.

6.

Moisture Control Diagnosis

button - to access the diagnostic screen for
factory trouble shooting.

by grain to get an accurate reading of
the grain moisture.

TRI-POINT MOISTURE CONTROLLER

20